娜美罗宾的双人调教里番agc_男男gay18无套全过程_精品久久av一区二区_亚洲国产一区heyzo_欧美VA亚洲VA日韩VA

山東綠環(huán)動力設(shè)備
Shandong Lvhuan Power Equipment
發(fā)電機組銷售 電站建設(shè)
發(fā)電機組配件 合作發(fā)電
客戶統(tǒng)一服務(wù)熱線:

151-650-44999
136-063-76139

當(dāng)前位置: 主頁 > 承接業(yè)務(wù) > 電站建設(shè) >

電站建設(shè)

發(fā)布時間:2022-06-13  來源:www.bgsnindia.com  閱讀數(shù): 次
山東綠環(huán)動力承接電站建設(shè)業(yè)務(wù) POWER STATION CONSTRUCTION。

電站建設(shè)
一、電站建設(shè)注意事項 Notice about Power plant construction

◎ 機房一般采用敞開式或是半開式,采用不發(fā)生火花的地面,地面平整易于清理。
◎ 如果采用閉式機房,應(yīng)按《建筑設(shè)計防火規(guī)范》(TJ16-74)中防爆設(shè)計要求設(shè)計,必須是單層建筑,門窗一律外開,設(shè)置大流量排放裝置,防止燃?xì)怏w積聚集。
◎ 機房與操作間應(yīng)隔開,不得直接連通,觀察窗應(yīng)雙層玻璃,且有鋼絲網(wǎng)防護。
◎ 必須有避雷裝置。
◎ 配備充足的滅火設(shè)備。
◎ 機房現(xiàn)場不能有明火,必須有明顯的“嚴(yán)禁煙火”等警示標(biāo)志。
◎ 發(fā)電機組排出的廢氣中,可能混有少量可燃?xì)怏w,要設(shè)計安裝由發(fā)動機引向室外的排氣管,排氣管系統(tǒng)應(yīng)連接可靠。
◎ Generator Room is usually constructed in open or semi-open type. The floor of generator room should be easily to clean and not easily to spark.
◎ If you want to construct closed generator room. You must construct a single-storey building. The open direction of all the doors and windows must turn outside. Please install some big capacity displacement device to avoid gas gathering.
◎ Generator room and the operation room must be separated, can not be directly connected. The observation window should be with double- deck glass protected by steel wire mesh.
◎ Lightning arrester is necessary.
◎ Prepare enough fire extinguishing appliances.
◎ "No Fire" mark should be obvious, open flame in the generator room is not allowed.
◎ In the exhaust gas, there might be a small amount of combustible gas. So the exhaust pipe of the generator must be leaded to outside of room. The exhaust pipe must be connected tightly.

二、機房設(shè)備要求 Requirements for the Equipments in Generator Room
◎機房內(nèi)的電氣設(shè)備必須防爆,進行維修時,必須切斷電源。
◎在燃?xì)夤艿肋M房處,設(shè)置緊急閥門,以備廠房發(fā)生緊急情況時,可迅速切斷氣源,此閥門應(yīng)離操作間很近。
◎要有氣體檢測報警系統(tǒng),以檢測漏氣問題。
◎ Electric equipments in the generator room must be explosion proof. When you repair the equipments, must turn off the power.
◎ Fix an urgent valve at the intake where gas pipe is leaded into room. You can cut off the gas in time if it’s emergency. This valve should be close to the operation room.
◎ The alarm system of gas detecting is necessary to find out the gas leakage in time.

三、燃?xì)夤艿酪?Requirements for Gas pipe
◎燃?xì)夤艿酪笥脽o縫鋼管,管壁不應(yīng)過薄,接頭處必須密封可靠,管道連接后要用燃?xì)鈾z測儀或是肥皂水檢測管線滲漏情況。
◎定期檢查閥門和管道,應(yīng)無燃?xì)庑孤┣闆r、無管道破損情況。
 
◎ All the gas pipes should adopt seamless steel tube, the pipe well should not be very thin, the connector of pipe should be sealed tightly. After connecting, please detect the leakage situation by gas detector or soap suds.
◎ Check the valve and pipe regularly, make sure there is no leakage and breakage situation.

山東綠環(huán)動力電站建設(shè)咨詢熱線:15165044999,歡迎前來咨詢洽談。

Copyright © 2002-2022 山東綠環(huán)動力  ICP備案:魯ICP備2022019158號-1